Cooling units made from cooling profiles
The cooling units in the PK series are characterised by high heat dissipation. The already face-milled surface (RZ max. 10 µm) is ready for installation and customised lengths and machining are available on request.
| Width [mm]: | 240.0 | |
| Height [mm]: | 121.0 | |
| Length [mm]: | 338.0 | |
| Fan Voltage [V] | 230.0 | |
| Min. thermal resistance [K/W]: | 0.042 | |
| Unit Weight [g]: | 11179.0 | |
| Max. power loss [W]: | 1850.0 |
| Width [mm]: | 240.0 | |
| Height [mm]: | 121.0 | |
| Length [mm]: | 168.0 | |
| Pressure chamber length [mm]: | 30.0 | |
| Fan Voltage [V] | 24.0 | |
| Min. thermal resistance [K/W]: | 0.065 | |
| Unit Weight [g]: | 3793.0 | |
| Max. power loss [W]: | 1200.0 |
| Width [mm]: | 240.0 | |
| Height [mm]: | 121.0 | |
| Length [mm]: | 368.0 | |
| Pressure chamber length [mm]: | 30.0 | |
| Fan Voltage [V] | 24.0 | |
| Min. thermal resistance [K/W]: | 0.031 | |
| Unit Weight [g]: | 11179.0 | |
| Max. power loss [W]: | 2500.0 |
