Ventilation units in louvered sections
Motorised fan units with axial and tangential fans, also suitable for double-sided installation
- Optimised thanks to special louver construction
- If required, two opposing mounting surfaces are available for mounting the semiconductor modules to be cooled.
- The technical data relates to the installation of a milled flat mounting surface with uniform load distribution.
- The pressure chamber between the fan and the finned unit ensures optimum air distribution to all fins.
- The safety regulations in accordance with the Technical Work Equipment Act must be observed.
General technical data :
- To protect against corrosion, the aluminium components are chromated (RoHS-compliant).
- Flat milled mounting surface (RZ max. 10 µm)
- Material AlMgSi 0.5 F22
- Insertion channels for M5 threaded nuts to DIN 562
Width [mm]: | 104.5 | |
Height [mm]: | 80.0 | |
Length [mm]: | 278.0 | |
Pressure chamber length [mm]: | 200.0 | |
Min. thermal resistance [K/W]: | 0.13 | |
Unit Weight [g]: | 2300.0 | |
Max. power loss [W]: | 200.0 |
Width [mm]: | 140.0 | |
Height [mm]: | 120.0 | |
Length [mm]: | 293.0 | |
Pressure chamber length [mm]: | 200.0 | |
Min. thermal resistance [K/W]: | 0.07 | |
Unit Weight [g]: | 4200.0 | |
Max. power loss [W]: | 400.0 |
Width [mm]: | 182.0 | |
Height [mm]: | 80.0 | |
Length [mm]: | 278.0 | |
Pressure chamber length [mm]: | 200.0 | |
Min. thermal resistance [K/W]: | 0.07 | |
Unit Weight [g]: | 4046.0 | |
Max. power loss [W]: | 400.0 |
Width [mm]: | 210.0 | |
Height [mm]: | 130.0 | |
Length [mm]: | 310.0 | |
Pressure chamber length [mm]: | 200.0 | |
Min. thermal resistance [K/W]: | 0.044 | |
Unit Weight [g]: | 5220.0 | |
Max. power loss [W]: | 625.0 |